V2000-c Rfid Access Control User Manual -

A: Yes. Any Wiegand 26/34 output device can connect to terminals 10(+), 11(D0), 12(D1), and GND. The V2000-c will treat the fingerprint ID as a card ID.

| Problem | Likely cause | Solution | |---------|--------------|----------| | No power | Wrong voltage | Check 12V DC, min 1A | | Card not beeping | Wrong RFID frequency | Use correct card type (125kHz EM) | | Green LED but lock doesn’t open | Relay wiring wrong | Check NO/COM or NC/COM based on lock type | | Buzzer long beep after card | User not enrolled | Add user via programming | | Door open too long alarm | Door contact stuck | Adjust sensor position or disable with 04 0# | V2000-c Rfid Access Control User Manual

Move the internal jumper (often labeled or S16 ) to pins 1-2 . Power the device on and wait for the beeps. Power off again and move the jumper back to pins 2-3 . A: Yes