Jungheinrich Eje 120 Error Code 4372 Work (2024)
In plain English: When the operator attempts to lift a load, the lift pump controller detects that the battery voltage drops too low too quickly . Furthermore, the current being drawn by the lift motor does not match what the computer expects based on the weight being lifted.
Clear faults and reproduce
This error is frequently tied to the and the "neutral zone" of the tiller. jungheinrich eje 120 error code 4372 work
The EJE 120 typically uses a 24V lead-acid or lithium-ion battery. If the battery voltage drops below 20V under load (lifting), the controller triggers code 4372. A battery with a dead cell will show good resting voltage (e.g., 24.5V) but collapse to 18V under load. In plain English: When the operator attempts to